Comparison and agreement between arterial versus venous blood gas analysis and pulse oxymetry in children with acute asthma

Authors

  • Sreenath G. Nair Department of Pediatrics, Pushpagiri Institute of Medical Sciences, Thiruvalla, Kerala, India
  • Carol Sara Cherian Department of Pediatrics, Pushpagiri Institute of Medical Sciences, Thiruvalla, Kerala, India
  • S. Sushmabai Department of Pediatrics, Pushpagiri Institute of Medical Sciences, Thiruvalla, Kerala, India

DOI:

https://doi.org/10.18203/2320-6012.ijrms20223633

Keywords:

Acute asthma, Arterial, Correlation agreement, Pulse oximetry, Venous blood gas analysis

Abstract

Background: Blood gas analysis is critical in managing children in intensive care unit primarily in respiratory disorders. This study aimed to ascertain agreement between the arterial and peripheral venous measurement of pH, pCO2, pO2 and bicarbonate levels along with SpO2 in acute asthma.

Methods: Hospital based cross sectional analytical study was conducted at Pushpagiri Institute of Medical Sciences in 50 children within the age group of 5-15 years who presented with symptoms suggestive of acute asthma with a modified PSI>6 after informed consent from parents and assent from child. SpO2 monitoring and ABG simultaneously with VBG were done immediately after admission. Statistical analysis was done to find out any correlation using Pearson correlation coefficient and Bland Altman plots were drawn to assess agreement.

Results: 50 children in the age group 5 years to 15 years were included in the study. Arterial pH and venous pH were found to be correlated significantly, Pearson correlation coefficient r=0.438. There was a good correlation between the arterial and venous pCO2 with r= 0.610, bicarbonate values r=0.608. There was poor correlation between arterial PO2 and venous PO2 values (r=0.030). The bias plot for pH and pCO2 showed moderate agreement in with 95% limits of agreement being in acceptably narrow range. The mean bias in pH was 0.0242 (SD=0.04912, 95% limits of agreement = -0.0721 to 0.12045); bias in pCO2 was -4.04400 (SD=5.53616, 95% limits of agreement = -14.8949 to 6.8069), and in bicarbonate levels -0.0940 (SD=2.09, 95% limits of agreement = -4.1998 to 4.0119).

Conclusions: Even though there was a good correlation and a moderate agreement between ABG and VBG parameters like pH, pCO2 and bicarbonate, VBG cannot be replaced for ABG in acute asthma. Pulse oximetry also has limitations in children with acute severe asthma as compared to ABG value.

 

Metrics

Metrics Loading ...

Author Biography

Carol Sara Cherian, Department of Pediatrics, Pushpagiri Institute of Medical Sciences, Thiruvalla, Kerala, India

Associate professor pediatrics

References

Malley WJ. Clinical Blood Gases: Assessment and Intervention. 2nd edn. Elsevier Saunders, Missouri; 2005:3-4.

Padmavathi K, Sumangali P, Subash Y. Arterial blood gas analysis in acute and chronic bronchial asthma. Bull Pharm Med Sci. 2013;1:200-6.

Toftegaard M, Rees SE, Andreassen S. Correlation between acid-base parameters measured in arterial blood and venous blood sampled peripherally, from vena cava superior, and from the pulmonary artery. Eur J Emerg Med. 2008;15:86-91.

Malatesha G, Singh NK, Bharija A, Rehani B, Goel A. Comparison of arterial and venous pH, bicarbonate, pCO2 and pO2 in initial emergency department assessment. Emerg Med J. 2007;24:569-71.

Kelly AM, McAlpine R, Kyle E. Venous pH can safely replace arterial pH in the initial evaluation of patients in the emergency department. Emerg Med J. 2001;18:340-2.

Rees SE, Hansen A, Toftegaard M, Pedersen J, Kristiensen SR, Harving H. Converting venous acid-base and oxygen status to arterial in patients with lung disease. Eur Respir J. 2009;33:1141-7.

Plüddemann A, Thompson M, Heneghan C, Price C. Pulse oximetry in primary care: primary care diagnostic technology update. Br J Gen Pract. 2011;61(586):358-9.

Kliegman RM, Stanton BF, St Geme JW, Schor NF. Nelson Textbook of Pediatrics. 20th edn. Elsevier, Reed Elsevier India pvt limited, First South Asian Edition; 2016:1095.

Myles PS, Cui J. Using the Bland-Altman method to measure agreement with repeated measures. Br J Anaesth. 2007;99(3):309-11.

Sanya RE, Kirenga BJ, Worodria W, Okot-Nwang M. Risk factors for asthma exacerbation in patients presenting to an emergency unit of a national referral hospital in Kampala, Uganda. Afr Health Sci. 2014;14(3):707-15.

Koul PA, Khan UH, Wani AA, Eachkoti R, Jan RA, Shah S, Masoodi Z, Qadri SM, Ahmad M, Ahmad A. Comparison and agreement between venous and arterial gas analysis in cardiopulmonary patients in Kashmir valley of the Indian subcontinent. Ann Thorac Med. 2011;6(1):33.

Ak A, Ogun CO, Bayir A, Kayis SA, Koylu R. Prediction of arterial blood gas values from venous blood gas values in patients with acute exacerbation of chronic obstructive pulmonary disease. Tohoku J Exp Med. 2006;210:285-90.

Kirubakaran C, Gnananayagam JEJ, Sundaravalli EK. Comparison of blood gas values in arterial and venous blood. Indian J Pediatr. 2003;70(10):781-5.

Yıldızdas D, Yapıcıog˘lu H, Yılmaz HL, Sertdemir Y. Correlation of simultaneously obtained capillary, venous, and arterial blood gases of patients in a paediatric intensive care unit. Arch Dis Child 2004;89:176-80.

Razi E, Nasiri O, Akbari H, Razi A. Correlation of arterial blood gas measurements with venous blood gas values in mechanically ventilated patients. Tanaffos. 2012;11(4):30-5.

McKeever TM, Hearson G, Housley G, Reynolds C, Kinnear W, Harrison TW, et al. Using venous blood gas analysis in the assessment of COPD exacerbations: a prospective cohort study. Thorax. 2015;71(3):1-6.

Adhikari S, Shrestha SK, Srivastava B, Singh BB, Bhattarai MD. Correlation of arterial blood gas measurement with peripheral venous blood gas values in adult patients admitted in ICU. J Chitwan Med Coll. 2015;5(13):11-7.

Malatesha G, Singh NK, Bharija A, Rehani B, Goel A. Comparison of arterial and venous pH, bicarbonate, pCO2 and pO2 in initial emergency department assessment. Emerg Med J. 2007;24:569-71.

Razi E, Akbari H. A comparison of arterial oxygen saturation measured both by pulse oximeter and arterial blood gas analyzer in hypoxemic and non-hypoxemic pulmonary diseases. Turk Respir J. 2006;7(2):43-7.

Downloads

Published

2022-12-30

How to Cite

Nair, S. G., Cherian, C. S., & Sushmabai, S. (2022). Comparison and agreement between arterial versus venous blood gas analysis and pulse oxymetry in children with acute asthma. International Journal of Research in Medical Sciences, 11(1), 179–185. https://doi.org/10.18203/2320-6012.ijrms20223633

Issue

Section

Original Research Articles