Use of magnetic port finder for metallic foreign body extraction in hand

Authors

  • Osvaldo I. Guevara Valmaña Department of Plastic and Reconstructive Surgery, Dr. Manuel Gea González General Hospital, México City, Mexico https://orcid.org/0000-0003-4329-3774
  • Sebastian Triguieros-Guzman Department of Plastic and Reconstructive Surgery, Dr. Manuel Gea González General Hospital, México City, Mexico
  • Omar S. Fattel-Servin Department of Plastic and Reconstructive Surgery, Dr. Manuel Gea González General Hospital, México City, Mexico
  • Valentina Prieto-Vargas Department of Plastic and Reconstructive Surgery, Dr. Manuel Gea González General Hospital, México City, Mexico
  • Katia Balderas-Ruiz Hospital General 58 Instituto Mexicano del Seguro Social, México city, Mexico
  • Armando Apellaniz-campo Department of Plastic and Reconstructive Surgery, Dr. Manuel Gea González General Hospital, México City, Mexico
  • Daniela Tellez-Placios Department of Plastic and Reconstructive Surgery, Dr. Manuel Gea González General Hospital, México City, Mexico

DOI:

https://doi.org/10.18203/2320-6012.ijrms20234010

Keywords:

Foreign bodies, Magnetic finder, Hand injury

Abstract

Foreign bodies are defined as any foreign object that enters the human body due to various circumstances. FBs are a common reason for emergency department visits. The hand's complex vascular and nervous structures make aggressive exploration dangerous. FBs can be composed of various materials, making their detection with a single imaging study difficult. We propose using a magnetic tissue expander locator for intraoperative FB localization, presenting the case of a 50-year-old female patient who, after falling from her height, presented with a foreign body in her right hand. Due to the complexity of locating the FB, we used the magnetic finder, successfully extracting it without damaging any underlying structures. Use of magnetic tissue expander locators are effective, practical, and safe alternative to help for locating magnetic foreign bodies.

Metrics

Metrics Loading ...

References

Salati SA, Rather A. Missed foreign bodies in the hand: an experience from a center in Kashmir. Libyan J Med. 2010;12:5.

Anderson MA, Newmeyer WL, Kilgore ES. Diagnosis and treatment of retained foreign bodies in the hand. Am J Surg. 1982;144:63-7.

Guidi M, Lucchina S, Kim BS, Besmens I, Fiore PI, Altin N, et al. Metallic foreign body in the ulnar nerve in the Guyon's canal and Review of the Literature. Case Rep Plast Surg Hand Surg. 2021;8(1):98-101.

Carneiro BC, Cruz IAN, Chemin RN, Rizzetto TA, Guimarães JB, Silva FD, et al. Multimodality Imaging of Foreign Bodies: New Insights into Old Challenges. Radiographics. 2020;40(7):1965-86.

Dolderer JH, Kelly JL, Morrison WA, Penington AJ. Foreign-body retrieval using a rare earth magnet. Plast Reconstr Surg. 2004;113:1869-70.

Glazier JJ, Dixon SR. Skin injury following prolonged fluoroscopy: early and late appearances. QJM. 2012;105(6):571-3.

Berezowsky CA, Gutiérrez AE, Fresnedo JQ, Montero JR. Anatomical study of the superficial palmar arch, its relation to the Kaplan cardinal line and literature review. Revista Iberoamer Cirugía Mano. 2018;46(2):96-105.

Downloads

Published

2023-12-28

How to Cite

Guevara Valmaña, O. I., Triguieros-Guzman, S., Fattel-Servin, O. S., Prieto-Vargas, V., Balderas-Ruiz, K., Apellaniz-campo, A., & Tellez-Placios, D. (2023). Use of magnetic port finder for metallic foreign body extraction in hand. International Journal of Research in Medical Sciences, 12(1), 246–248. https://doi.org/10.18203/2320-6012.ijrms20234010

Issue

Section

Case Reports