Automatic detection of coronaries ostia in computed tomography angiography volume data

Authors

  • Noha A. Seada Faculty of Computer and Information Sciences, Ain Shams University, Egypt
  • Mostafa G. M. Mostafa Faculty of Computer and Information Sciences, Ain Shams University, Egypt

DOI:

https://doi.org/10.18203/2320-6012.ijrms20163517

Keywords:

Coronaries ostia, CTA, Harris corner detection, Ostia automatic detection

Abstract

Background: Heart coronaries emerge from the ascending aorta lateral sides from two points called the coronaries ostia. To automatically segment the heart coronaries; there must be a starting point (seed) for the segmentation. In this paper we present a fully automatic approach to segment the coronaries ostia towards automatic seeding for heart coronaries segmentation.

Methods: Our algorithm takes as an input a CTA volume of segmented aorta cross sections that represents our region of interest. Then the ostia detection algorithm traverses that volume looking for the ostia points in an automatic fashion. The proposed algorithm depends on the anatomical features of the ostia. The main anatomic feature of the ostia is that it appears like a curvature or corner on the segmented ascending aorta cross section. Therefore we adopted in our methodology a modified version of Harris Corner Detection; besides inducing some anatomical features of the ostia location with respect to the aortic valve.

Results: The proposed algorithm is tested and validated on the computed tomography angiography database provided by the Rotterdam coronary artery algorithm evaluation framework. The proposed automatic ostia detection algorithm succeeded to detect both ostia points in all the test cases. Also, the detected ostia points’ coordinates are validated versus a ground truth provided by the same framework with deviation between the results of the detection process and the ground truth having a min of 0 pixels and a max of 10 pixels for all test cases.

Conclusions: Thus the proposed algorithm gives accurate results in comparison with the ground truth, which proves the efficiency of the proposed algorithm and its applicability to be extended as a seed for heart coronaries segmentation.

References

Appropriate use of non-invasive testing for diagnosis of stable coronary artery.” [Online]. Available: https://www.escardio.org/ Journals/E-Journal-of-Cardiology-Practice/ Volume-12/ Appropriate-use-of-non-invasive-testing-for-diagnosis-of-stable-coronary-artery.

Seada NA, Hamad S, Mostafa MGM. “Automatically Seeded Region Growing Approach for Automatic Segmentation of Ascending Aorta,” in the 10th International Conference on Informatics and Systems. INFOS. 2016:145-50.

Gong Z, Shen Z, Zhang D, Wang C, Zhou S. One-click detection of coronary artery ostia from three-dimensional CTA data. 2015 IEEE Int. Conf. Inf. Autom. ICIA 2015 - conjunction with 2015 IEEE Int. Conf. Autom. Logist. 2015;877-80.

Hennemuth A, Boskamp T, Fritz D, Ku C. One-click coronary tree segmentation in CT angiographic images. Int Congress Series. 2005;1281:317-21.

Wang C, Smedby O. An automatic seeding method for coronary artery segmentation and skeletonization in CTA. Insight J. 2008:1-8.

Turner K, Navaratnam V. The positions of coronary arterial ostia. Clin Anat. 1996:9(6):376-80.

Thoracic Aorta Diagram Anatomy - Human Anatomy Chart.” [Online]. Available: http://humananatomychart.us/ thoracic-aorta-diagram-anatomy/. [Accessed: 29-Sep-2016].

Harris C, Stephens M. A Combined Corner and Edge Detector,” Procedings Alvey Vis. Conf. 1988:147-51.

Dey N, Nandi P, Barman N, Das D, Chakraborty S. A Comparative Study between Moravec and Harris Corner Detection of Noisy Images Using Adaptive Wavelet Thresholding Technique. IJERA. 2012;2(1):599-606.

Schaap M, Metz CT, Walsum TV, Giessen AGV, Weustink AC, Castro C, et al. Standardized evaluation methodology and reference database for evaluating coronary artery centerline extraction algorithms. Med Image Anal. 2009;13:701-14.

CIBC. ImageVis3D: An interactive visualization software system for large-scale volume data. 2014. [Online]. Available: http://www.imagevis3d.org.

Downloads

Published

2016-12-19

How to Cite

Seada, N. A., & Mostafa, M. G. M. (2016). Automatic detection of coronaries ostia in computed tomography angiography volume data. International Journal of Research in Medical Sciences, 4(11), 4747–4752. https://doi.org/10.18203/2320-6012.ijrms20163517

Issue

Section

Original Research Articles