Minimally invasive management of a comminuted bicondylar middle phalanx head fracture using Joshi’s external stabilization system: a case report

Authors

  • Sachin Sahuji Department of Orthopaedics, Aster RV Hospital, Bangalore, Karnataka, India
  • Vijay Raghav Kanakam Department of Orthopaedics, Aster RV Hospital, Bangalore, Karnataka, India
  • J. V. Srinivas Department of Orthopaedics, Aster RV Hospital, Bangalore, Karnataka, India

DOI:

https://doi.org/10.18203/2320-6012.ijrms20264210

Keywords:

Middle phalanx fracture, JESS, Mini-external fixator, Bicondylar intra-articular fracture, Capsulo-ligamentotaxis, Hand trauma

Abstract

Fractures of the middle phalanx head are uncommon injuries that pose a challenge in restoring articular congruity while preserving proximal interphalangeal (PIP) joint mobility and extensor tendon function. We report the case of a right-hand-dominant 29-year-old male software engineer who sustained a closed, comminuted bicondylar intra-articular fracture of the right little finger middle phalanx following a road traffic accident. Three days after injury, closed reduction under fluoroscopic guidance and percutaneous fixation using a modified Joshi’s External Stabilization System (JESS) was performed under regional anaesthesia. The construct comprised two 2.0-mm and two 1.6-mm Kirschner wires, four mini-clamps, and two connecting rods. The procedure lasted 30 minutes. The fixator was maintained for four weeks, followed by supervised rehabilitation. Radiographs at four weeks confirmed fracture union, maintained articular congruity, and no loss of reduction. At final follow-up, the patient achieved a total active motion of 220°, with MCP, PIP, and DIP joint arcs of 90°, 100°, and 30°, respectively. Grip strength recovered to 95% of the contralateral hand, and pain was minimal (VAS 1/10). The patient returned to full occupational computer work at four weeks, without pin-tract infection, joint stiffness, malunion, or hardware-related complications. This case highlights modified JESS fixation as a minimally invasive option for selected comminuted intra-articular fractures of the middle phalanx head. It may facilitate maintenance of reduction while preserving tendon gliding and supporting functional recovery through timely rehabilitation.

 

Metrics

Metrics Loading ...

References

Díaz-García R, Waljee JF. Current management of metacarpal fractures. Hand Clin. 2013;29(4):507-18. DOI: https://doi.org/10.1016/j.hcl.2013.09.004

Fitoussi F, Ip WY, Chow SP. External fixation for comminuted phalangeal fractures: a biomechanical cadaver study. J Hand Surg Br. 1996;21(6):760-4. DOI: https://doi.org/10.1016/S0266-7681(96)80182-3

Venkatesh V, Ravi GR. A rural perspective on the management of phalangeal and metacarpal fractures using mini external fixators/JESS: a prospective study. J Popul Ther Clin Pharmacol. 2025;32(1):303-12. DOI: https://doi.org/10.53555/kep37f42

Ravish VN, Bharath Raju G, Yadrami SP. Functional outcome of fractures of the hand treated with Joshi’s external stabilization system. Int J Res Orthop. 2026;12(4):1082-7. DOI: https://doi.org/10.18203/issn.2455-4510.IntJResOrthop20262044

Jha A, Dua A, Gadkari A, Yadav AK, Goyal N. Needle cap external fixator for proximal phalanx fracture: a case report. J Orthop Case Rep. 2022;12(10):107-9. DOI: https://doi.org/10.13107/jocr.2022.v12.i10.3388

Hara A, Yokoyama M, Ichihara S, Maruyama Y. Treatment of an intraarticular comminuted fracture of the base of the proximal phalanx in a ring finger using the Ichi-Fixator external fixator system: a case report. Int J Surg Case Rep. 2020;68:12-7. DOI: https://doi.org/10.1016/j.ijscr.2020.02.020

Naidu KVD. Management of metacarpal and phalangeal fractures with JESS fixator: a prospective study. Int J Orthop Sci. 2018;4(1):383-7. DOI: https://doi.org/10.22271/ortho.2018.v4.i1f.55

Singh J, Jain K, Mruthyunjaya, Ravishankar R. Outcome of closed proximal phalangeal fractures of the hand. Indian J Orthop. 2011;45(5):432-8. DOI: https://doi.org/10.4103/0019-5413.83764

Gudmundsen TE, Borgen L. Fractures of the fifth metacarpal. Acta Radiol. 2009;50(3):296-300. DOI: https://doi.org/10.1080/02841850802709201

Kurzen P, Fusetti C, Bonaccio M, Nagy L. Complications after plate fixation of phalangeal fractures. J Trauma. 2006;60(4):841-3. DOI: https://doi.org/10.1097/01.ta.0000214887.31745.c4

Stern PJ, Wieser MJ, Reilly DG. Complications of plate fixation in the hand skeleton. Clin Orthop Relat Res. 1987;(214):59-65. DOI: https://doi.org/10.1097/00003086-198701000-00010

Page SM, Stern PJ. Complications and range of motion following plate fixation of metacarpal and phalangeal fractures. J Hand Surg Am. 1998;23(5):827-32. DOI: https://doi.org/10.1016/S0363-5023(98)80157-3

Hattori Y, Doi K, Sakamoto S, Yamasaki H, Wahegaonkar A, Addosooki A. Volar plating for intra-articular fracture of the base of the proximal phalanx. J Hand Surg Am. 2007;32(8):1299-303. DOI: https://doi.org/10.1016/j.jhsa.2007.07.020

Joshi BB. Percutaneous internal fixation of fractures of the proximal phalanges. Hand. 1976;8(1):86-92. DOI: https://doi.org/10.1016/0072-968X(76)90069-3

Suzuki Y, Matsunaga T, Sato S, Yokoi T. The pins and rubbers traction system for treatment of comminuted intraarticular fractures and fracture-dislocations in the hand. J Hand Surg Br. 1994;19(1):98-107. DOI: https://doi.org/10.1016/0266-7681(94)90059-0

Badia A, Riano F, Ravikoff J, Khouri R, Gonzalez-Hernandez E, Orbay JL. Dynamic intradigital external fixation for proximal interphalangeal joint fracture dislocations. J Hand Surg Am. 2005;30(1):154-60. DOI: https://doi.org/10.1016/j.jhsa.2004.07.019

Finsen V. Suzuki’s pins and rubber traction for fractures of the base of the middle phalanx. J Plast Surg Hand Surg. 2010;44(4-5):209-13. DOI: https://doi.org/10.3109/02844311.2010.494416

Sastravaha N, Limudomporn K, Taweewuthisub W. A novel technique for dynamic external fixation of proximal interphalangeal joint fracture-dislocations. J Hand Surg Asian Pac Vol. 2020;25(4):427-33. DOI: https://doi.org/10.1142/S2424835520500460

Kapur B, Paniker J, Casaletto J. An alternative technique for external fixation of traumatic intra-articular fractures of proximal and middle phalanx. Tech Hand Up Extrem Surg. 2015;19(4):163-7. DOI: https://doi.org/10.1097/BTH.0000000000000102

Schuind F, Donkerwolcke M, Burny F. External minifixation for treatment of closed fractures of the metacarpal bones. J Orthop Trauma. 1991;5(2):146-52. DOI: https://doi.org/10.1097/00005131-199105020-00005

Salunkhe RM, Joshi H, Pisal TK, Biswas SK, Patel JJ, Singh A. A prospective study of dynamic treatment of fracture phalanx and metacarpals of the hand with Kirschner-wire fixation/external fixator and finger splint: daycare management (30 cases). Med J Dr DY Patil Univ. 2016;9(6):708-13. DOI: https://doi.org/10.4103/0975-2870.194187

Drenth DJ, Klasen HJ. External fixation for phalangeal and metacarpal fractures. J Bone Joint Surg Br. 1998;80(2):227-30. DOI: https://doi.org/10.1302/0301-620X.80B2.0800227

Downloads

Published

2026-10-31

How to Cite

Sahuji, S., Kanakam, V. R., & Srinivas , J. V. (2026). Minimally invasive management of a comminuted bicondylar middle phalanx head fracture using Joshi’s external stabilization system: a case report . International Journal of Research in Medical Sciences, 14(11), 5426–5432. https://doi.org/10.18203/2320-6012.ijrms20264210

Issue

Section

Case Reports