Evaluation of functional outcome following internal fixation of femoral neck fracture with cannulated cancellous screws: a prospective study from Bangladesh

Authors

  • M. Azizur Rahman Department of Orthopaedic Surgery, National Institute of Traumatology and Orthopedic Rehabilitation (NITOR), Dhaka, Bangladesh
  • Muhammad Anwar Hossen Department of Ilizarov & Deformity Correction, National Institute of Traumatology and Orthopedic Rehabilitation (NITOR), Dhaka, Bangladesh
  • Md Sahidur Rahman Khan Department of Orthopaedics & Traumatology, National Institute of Traumatology and Orthopedic Rehabilitation (NITOR), Dhaka, Bangladesh
  • M. Samsul Arefin Department of Orthopaedic Surgery, Kushtia Medical College, Kushtia, Bangladesh
  • Shahnewas Department of Orthopaedic Surgery, National Institute of Traumatology and Orthopedic Rehabilitation (NITOR), Dhaka, Bangladesh
  • M. Selim Reza Department of Orthopaedic Surgery, National Institute of Traumatology and Orthopedic Rehabilitation (NITOR), Dhaka, Bangladesh
  • M. Mohsin Mia Department of Ilizarov & Deformity Correction, National Institute of Traumatology and Orthopedic Rehabilitation (NITOR), Dhaka, Bangladesh

DOI:

https://doi.org/10.18203/2320-6012.ijrms20264164

Keywords:

Femoral neck fracture, Cannulated cancellous screws, Harris hip score, Asvascular necrois

Abstract

Background: Femoral neck fracture is a significant cause of morbidity in adults admitted to tertiary care centers in Bangladesh, and internal fixation with cannulated cancellous screws is the preferred head-preserving procedure in physiologically fit patients. This study aimed to assess the functional results, radiological healing, and complication rate of cannulated cancellous screw fixation of femoral neck fractures.

Methods: This concurrent prospective observational study was carried out at the Department of Orthopaedic Surgery, National Institute of Traumatology and Orthopedic Rehabilitation (NITOR), Dhaka, Bangladesh, from January 2024 to December 2024, on 45 patients with femoral neck fracture who were treated with closed or open reduction and internal fixation with 3 or 4 cannulated cancellous screws. Demographic, fracture, and operative data were collected, and functional outcome was evaluated at 3, 6, and 12 months after surgery using the Harris Hip Score (HHS). The data were analyzed using SPSS version 26.

Results: The age group 31-40 years was the largest (24.4%), and there was a significant male predominance (71.1%). The most common mechanism of injury was road traffic accidents (53.3%). The most common fracture type was type III (37.8%), and the majority of fractures (86.7%) were closed reduction with anatomical alignment. Radiological union was obtained in 91.1% of patients, avascular necrosis in 11.1%, and shortening of the femur in 15.6%. The percentage of patients with excellent-to-good HHS increased from 22.2% at 3 months to 68.9% at 12 months.

Conclusion: Although early diagnosis, early surgery, and anatomical reduction are key to reducing complications, the union rate and functional recovery are progressive and favorable for femoral neck fractures treated with cannulated cancellous screw fixation.

References

Slobogean GP, Sprague SA, Scott T, McKee M, Bhandari M. Management of young femoral neck fractures: is there a consensus? Injury. 2015;46(3):435–40.

Slobogean GP, Sprague SA, Scott T, Bhandari M. Complications following young femoral neck fractures. Injury. 2015;46(3):484–91.

Stockton DJ, Lefaivre KA, Deakin DE, Osterhoff G, Yamada A, Broekhuyse HM, et al. Incidence, magnitude, and predictors of shortening in young femoral neck fractures. J Orthop Trauma. 2015;29(9):e293–8.

Ye Y, Hao J, Mauffrey C, Hammerberg EM, Stahel PF, Hak DJ. Optimizing stability in femoral neck fracture fixation. Orthopedics. 2015;38(10):625–30.

Kazley JM, Banerjee S, Abousayed MM, Rosenbaum AJ. Classifications in brief: Garden classification of femoral neck fractures. Clin Orthop Relat Res. 2018;476(2):441–5.

Stoffel K, Zderic I, Gras F, Sommer C, Eberli U, Mueller D, et al. Biomechanical evaluation of the femoral neck system in unstable Pauwels III femoral neck fractures: a comparison with the dynamic hip screw and cannulated screws. J Orthop Trauma. 2017;31(3):131–7.

Turgut A, Kumbaracı M, Kalenderer Ö, İlyas G, Bacaksız T, Karapınar L. Is surgeons' experience important on intra- and inter-observer reliability of classifications used for adult femoral neck fracture? Acta Orthop Traumatol Turc. 2016;50(6):601–5.

Nauth A, Creek AT, Zellar A, Lawendy AR, Dowrick A, Gupta A, et al. Fracture fixation in the operative management of hip fractures (FAITH): an international, multicentre, randomised controlled trial. Lancet. 2017;389(10078):1519–27.

Nandi S. Revisiting Pauwels' classification of femoral neck fractures. World J Orthop. 2021;12(11):811.

Lee YK, Yoon BH, Hwang JS, Cha YH, Kim KC, Koo KH. Risk factors of fixation failure in basicervical femoral neck fracture: which device is optimal for fixation? Injury. 2018;49(3):691–696.

Mannan M, Ahmad Z, Shah SM, Tayyab M, Karim F, Shan RR, et al. Frequency and classification of

femoral neck fractures: a cross-sectional study from a tertiary care hospital in Peshawar, Pakistan. Cureus. 2025;17(10).

Patil P, Shivade N, Nikam M. A comparative study of treatment outcomes of femur neck fracture with dynamic hip screws versus multiple cancellous cannulated screws. Int J Health Sci. 2022;(I):7050–8.

Lim EJ, Shon HC, Cho JW, Oh JK, Kim J, Kim CH. Dynamic hip screw versus cannulated cancellous screw in Pauwels type II or type III femoral neck fracture: a systematic review and meta-analysis. J Pers Med. 2021;11(10):1017.

Wen M, Wang S, Wang L, Wang Y, Dai S, Liu W, et al. Femoral neck system versus cannulated screws combined with medial plate for femoral neck fractures in young and middle-aged patients: a prospective multicenter randomized controlled trial. J Orthop Surg Res. 2025;20(1):559.

Caldaria A, Gambuti E, Biagi N, Spadoni E, Saracco A, Massari L, et al. Comparison of femoral neck system versus cannulated cancellous screws for the fixation of femoral neck fracture: a single-center retrospective cohort study. Eur J Orthop Surg Traumatol. 2024;34(6):3207–13.

Jettoo P, James P. Dynamic hip screw fixation versus multiple screw fixation for intracapsular hip fracture. J Orthop Surg (Hong Kong). 2016;24(2):146–9.

Kunwar A, Manjhi B, Maheshwari P, Kumar U, Kumar S, Ranjan RK, et al. Comparing the clinical and radiological outcome of femoral neck system versus dynamic hip screw in femoral neck fractures. Cureus. 2025;17(11).

Siavashi B, Aalirezaei A, Moosavi M, Golbakhsh MR, Savadkoohi D, Zehtab MJ. A comparative study between multiple cannulated screws and dynamic hip screw for fixation of femoral neck fracture in adults. Int Orthop. 2015;39(10):2069–71.

Widhalm HK, Arnhold R, Beiglböck H, Munteanu A, Lang NW, Hajdu S. A comparison of dynamic hip screw and two cannulated screws in the treatment of undisplaced intracapsular neck fractures—two-year follow-up of 453 patients. J Clin Med. 2019;8(10):1670.

Raj JJ, Kow RY, Ganthel K, Kunasingh DE, Panicker GK, Lim BC, et al. Outcomes of femoral neck fractures in young patients and the factors associated with complications: a multicenter study from Malaysia. Cureus. 2021;13(9):e18110.

Medda S, Snoap T, Carroll EA. Treatment of young femoral neck fractures. J Orthop Trauma. 2019;33(Suppl 1):S1–6.

Downloads

Published

2026-10-31

How to Cite

Rahman, M. A., Hossen, M. A., Khan, M. S. R., Arefin, M. S., Shahnewas, Reza, M. S., & Mia, M. M. (2026). Evaluation of functional outcome following internal fixation of femoral neck fracture with cannulated cancellous screws: a prospective study from Bangladesh. International Journal of Research in Medical Sciences, 14(11), 5069–5074. https://doi.org/10.18203/2320-6012.ijrms20264164

Issue

Section

Original Research Articles